BURKERT Type 3361 (SKU 20138290) electromotive 2-way globe control valve. Features DN 10 flange connection, 24 V DC supply, 0-25 bar operating pressure, and stainless steel body.

BURKERT Type 3361 (SKU 20138290) is an innovative electromotive 2-way globe control valve designed for demanding operating conditions. The electromotive actuator with a ball screw positions the control cone with the highest precision. A unique feature is its high positioning speed of up to 6 mm/s, which reacts almost delay-free to process signals and can be varied according to customer demands. Pressure variations or shocks in the medium are not transferred to the valve position. Each flow-optimised valve body can be equipped with up to 5 different valve seats for precise adaptation to customer needs.
If necessary, the safety position can be approached by an optional energy storage (SAFEPOS energy-pack) in case of a power failure. The actuator and valve are perfectly adapted to each other with a closed design and robust surface, ensuring the hygienic requirements of fast and residue-free cleaning. Harsh environmental conditions are no problem for the Type 3361 due to its IP65/IP67 degree of protection and high impact and vibration resistance.
| Product Properties | Specification |
|---|---|
| Design | Globe control valve |
| Nominal diameter | DN 10...DN 100, NPS 3/8...4 |
| Safety setting (power failure) | With SAFEPOS energy-pack: open, closed or freely programmable position. Without: blocked in last position |
| Flow direction | Against closing direction (below seat) |
| Controller variant | Positioner or process controller (option) |
| Operating pressure | 0...25 bar(g), 40 bar(g) on request. Vacuum variant down to -0.9 bar(g) (optional) |
| Nominal pressure | PN 25/PN 40 (DIN EN 1333), Class 150 (DIN EN 1759) |
| Flow characteristic | Equal percentage, linear (on request) |
| Seat leakage | Class III, IV and VI (DIN EN 60534-4) |
| Theoretical rangeability | Up to 50:1 |
| Operating voltage | 24 V DC ± 10 % (maximum residual ripple 10 %) |
| Protection class | III (DIN EN 61140) |
| Duty cycle | 100 % |
| Operating medium | Steam, neutral gases, water, alcohols, oils, fuels, hydraulic fluids, salt solutions, organic solvents, oxygen (optional), hydrogen (optional), lyes (optional) |
| Medium temperature | -40 °C...+230 °C |
| Degree of protection | IP65/IP67 (DIN EN 60529), NEMA 4X |

| Component | Material |
|---|---|
| Display housing / blind cover | PPS (standard), stainless steel 1.4301 (for ATEX/IECEx) |
| Actuator cover | PPS (AG2) / PC (AG3) |
| Seal | EPDM |
| Actuator housing | Powder-coated aluminium |
| Actuator base | PPS (AG2) / Stainless steel 1.4308 (AG3) |

| Component | Material |
|---|---|
| Spindle | Stainless steel 1.4401 (316) / 1.4404 (316L) |
| Spindle seal | PTFE V-seals (filled) with spring compensation |
| Spindle guide | Stainless steel 1.4404 (316L) |
| Packing gland tube | Stainless steel 1.4401 (316) |
| Seal valve body | Graphite or PTFE |
| Seat seal | Stainless steel 1.4571 (optionally hardened), PTFE or PEEK seal washer |
| Control cone | Stainless steel 1.4571 (optionally hardened) |
| Valve seat | Stainless steel 1.4571 (optionally hardened) |
| Valve body | Stainless steel CF3M |
The electromotive linear drive consists of a brushless DC motor, a gear, and a spindle system that transfers the force to the closing element. The integrated electronics are controlled either by standard signals or via a fieldbus (digital). A positioner and a process controller are available as controller variants.

SAFEPOS energy-pack
The optional energy storage device SAFEPOS energy-pack is available for the device. If the supply voltage fails, it supplies the actuator with the energy required to move the valve into the desired position, which can be set in the menu.
The position of the actuator (stroke) is controlled according to the position set-point value. The position set-point value is specified either by an external standard signal (analogue) or via a fieldbus (digital). The displacement transducer records the actual position (POS) of the electric linear actuator. The positioner compares the actual position value with the position set-point value (CMD). If there is a system deviation, the electric motor drive is controlled via the actuating variable CTRL and the actual position value is changed accordingly.
The additionally implemented PID controller allows process control. The set-point position of the valve is calculated from the external signal (e.g., level, pressure, flow rate, temperature) for the process set-point and the actual process value via the control parameters (PID controller).
Operating Limits
The maximum permissible temperature for the environment and the medium are dependent on each other. For particularly demanding process conditions such as cavitation, erosion by wet steam, or abrasive media, hardened cones and seats can be used to significantly increase the service life.