Skip to content
12 Valve SlotsIndustrial EthernetAirLINE Quick Stainless SteelPneumatic HotSwap24 Digital InputsIP20 / IP65 Cabinet

BURKERT 20033486 Type 8652 AirLINE 12-Slot Valve Island with Industrial Ethernet and Stainless Steel AirLINE Quick

BURKERT 20033486 Type 8652 AirLINE 12-slot valve island features 10 bistable 5/2-way valves, 2 blind plates, 24 digital inputs, stainless steel AirLINE Quick plate, HotSwap, and Industrial Ethernet.

BURKERT 20033486 Type 8652 AirLINE 12-Slot Valve Island with Industrial Ethernet and Stainless Steel AirLINE Quick

BURKERT 20033486 (Type 8652) is a 12-slot AirLINE valve island configured for process automation applications, combining high pneumatic density with multi-protocol Industrial Ethernet communications. This pre-assembled unit is fitted with ten bistable 5/2-way impulse solenoid valves (circuit function Z) across valve slots 1 through 10, accompanied by two blind plates at positions 11 and 12 for future expansion. The valve island incorporates three 8-channel digital input modules (24 DI total) to collect discrete sensor signals directly at the pneumatic manifold.

Designed specifically for installation on control cabinet floors or rear panels, the assembly integrates a stainless steel 1.4301 AirLINE Quick adapter plate with stainless steel pneumatic fittings. The process connections comprise D10 mm push-in air supply lines and D6 mm push-in working ports. Pneumatic safety mechanisms include integrated check valves in exhaust ports 3 (R) and 5 (S) to suppress pressure peaks, as well as a pneumatic HotSwap function at port 1 (P) that allows valve replacement during continuous system operation.

BURKERT 20033486 Type 8652 AirLINE valve island overview

Pneumatic Configuration and Valve Functions ​

The 12-station manifold operates with an internal auxiliary pilot air supply across an operating pressure range of -1.0 bar to 10.0 bar (vacuum up to 10 bar) and a pilot pressure requirement of 3.0 bar to 10.0 bar. Each 11 mm wide valve station is serviced by a low-power pilot valve (Type 6164) actuating the Type 6534 pneumatic spool valve.

Positions 1 to 10 utilize circuit function Z (CF Z), which provides a 5/2-way bistable impulse function with two coils and integrated manual overrides. Pressure applied at port 1 directs output pressure alternately to port 2 or port 4. Once pulsed, the valve retains its switched position until the opposing coil is energized. Positions 11 and 12 are blanked off using dedicated dummy plates (article 335779).

Valve PositionFunction TypeCircuit Function Symbol / DesignationManual OverrideNominal Width
Position 1 to 105/2-way bistable impulse valveCircuit function Z (CF Z), dual coilLatching / spring return4 mm
Position 11Blind plateDummy plate module——
Position 12Blind plateDummy plate module——

Standard Type 8652 valve stations deliver a nominal flow rate $Q_{\text{Nn}}$ of 310 l/min (measured with air at +20 °C, 6 bar inlet pressure, and 1 bar differential pressure). When utilizing the integrated pneumatic HotSwap function in supply port 1, the nominal flow rate is reduced by approximately 3% to 290–300 l/min.

Pilot Air Quality

Operate the valve island with dry, oil-free or lubricated compressed air complying with ISO 8573-1:2010 Class 7.4.4. Upstream filtration to 5 µm is recommended to ensure long operating life.

AirLINE Quick Stainless Steel Mounting System ​

The unit is equipped with the AirLINE Quick adapter system constructed from stainless steel 1.4301, complemented by working push-in couplings made of stainless steel 1.4401. This configuration allows direct mechanical mounting into a cutout on the bottom or wall of the control cabinet. Pneumatic supply and working lines connect on the outside of the enclosure, eliminating cabinet bulkhead fittings, reducing internal tubing clutter, and minimizing overall cabinet volume.

BURKERT 20033486 Type 8652 AirLINE Quick adapter plate in stainless steel

FeatureSpecification
Adapter Plate MaterialStainless steel 1.4301
Pneumatic Fitting MaterialStainless steel 1.4401
Supply / Exhaust PortsPush-in connector D10 mm (3/8")
Working Ports (2 and 4)Push-in connector D6 mm (1/4")
Auxiliary Supply (Left)Additional D6 mm and D10 mm push-in connectors
Enclosure RatingIP65 when mounted in a closed control cabinet; NEMA 250 Type 4X

Digital Input Electronic Modules (24 DI) ​

BURKERT 20033486 incorporates three 8-channel digital input (8DI) electronic modules, providing 24 independent inputs for reading feedback signals from pneumatic actuators, process valves, or position sensors. Sensors are powered with 24 V DC directly from the electronic module, with current consumption limited to a maximum of 30 mA per digital input.

BURKERT 20033486 Type 8652 electronic module with digital inputs

ParameterSpecification Value
Compatible Sensors2-wire sensors (10–30 V), 3-wire sensors, mechanical limit switches
Switching Thresholds$V_{\text{OFF}} = 0\dots5\text{ V DC}$, $V_{\text{ON}} = 10\dots30\text{ V DC}$
Input Current at $V_{\text{ON}}$Max. 5.7 mA per channel (typical at 24 V DC)
Input Impedance> 4 kΩ
Diagnostic FunctionsOpen-circuit detection (2-wire sensors), short-circuit detection (3-wire sensors)
Galvanic IsolationNo; all input channels share a common reference potential
Maximum Cable Length< 30 m (conductor cross-section $\le 1.5\text{ mm}^2$)

Depending on the connected sensor technology, the digital input module reports diagnostic status directly on the integrated LC display and over the fieldbus:

Reported Sensor State3-Wire Sensor2-Wire SensorMechanical Limit Switch
Sensor ActuatedYesYesYes
Sensor Not ActuatedYesYesYes
Short-Circuit FaultYes——
Wire-Break Fault—Yes—

ME43 Fieldbus Gateway and Industrial Ethernet Interface ​

Communications are managed through an integrated Type ME43 fieldbus gateway module supporting Industrial Ethernet protocols: PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, and CC-Link IE Field Basic, along with PROFINET S2 system redundancy for high-availability architectures. The physical interface consists of two shielded RJ45 ports (X1 and X2) enabling line or ring network topologies without requiring external industrial switches.

BURKERT 20033486 Type 8652 Industrial Ethernet network topology with slave islands

The illuminated LC display provides status indication, valve cycle counts, and diagnostic messages formatted in clear text and graphic symbols. Diagnostic messages are simultaneously transferred to the higher-level PLC. For engineering and configuration, the unit interfaces with the Bürkert Communicator software (Type 8920) via büS.

PinRJ45 Signal Assignment (X1 / X2)
1TX+ (Transmit Data +)
2TX- (Transmit Data -)
3RX+ (Receive Data +)
4N.C. (Not connected)
5N.C. (Not connected)
6RX- (Receive Data -)
7N.C. (Not connected)
8N.C. (Not connected)

Electrical Connections and Dual Power Supply ​

The island utilizes electrically segregated power feeds for the digital electronics and the pneumatic solenoid coils. Separate power routing protects communication networks from inductive switching transients and permits independent safety disconnection of valve coils.

BURKERT 20033486 Type 8652 modular assembly and 24 V interface plate

Communication and Display Supply (5-Pin Spring Terminal) ​

TerminalWire ColorAssignment
1Red+24 V DC electronics power
2WhiteCAN_H (büS connection)
3GreenShielding
4BlueCAN_L (büS connection)
5BlackGND (0 V DC)

Pneumatic Valve Coil Supply (2-Pin Spring Terminal) ​

TerminalClip NumberWire ColorAssignment
AUX 24 V1Red+24 V DC auxiliary valve power
GND2BlackGND (0 V DC valve ground)

Electrical Limits

Conductor cross-sections up to 1.5 mm² are supported by both spring-loaded terminal blocks. Transient overvoltage suppression must be configured so that peak surges do not exceed 140% of the 24 V DC nominal supply voltage.

Dimensions and Control Cabinet Mounting ​

BURKERT 20033486 has a 12-slot width profile. Mechanical installation can be completed directly through cabinet base cutouts using AirLINE Quick or mounted onto standard DIN rails (EN 50022 35 × 7.5 mm or 35 × 15 mm).

BURKERT 20033486 Type 8652 dimensional drawing for 4-, 8-, and 12-fold variants

VariantDimension A [mm]Dimension B [mm]Fixing Screws CPitch mPitch n
4-fold66—4 × M531
8-fold351118 × M572
12-fold (20033486)7715410 × M5113

For reference across the Type 8652 family, larger manifold profiles include intermediate feed modules as detailed below:

VariantA [mm]B [mm]Screws CD [mm]m$m'$n
16-fold with intermediate feed11222410 × M5114.3774
20-fold with intermediate feed13426810 × M5158.31175
24-fold with intermediate feed15631210 × M5158.311116
16-fold without intermediate feed9919810 × M5—15—4
20-fold without intermediate feed12124210 × M5—19—5
24-fold without intermediate feed14328610 × M5—23—6

Cabinet Installation Clearances ​

When positioning the valve terminal inside an enclosure, maintain minimum clearances between the terminal front edge and the cabinet door to permit hot swapping of solenoid valves.

BURKERT 20033486 Type 8652 control cabinet installation spacing for HotSwap clearance

General Technical Specifications ​

CategoryParameterSpecification Value
MaterialsHousing BodyPolyamide (PA)
SealsNBR and PUR
AirLINE Quick BaseStainless steel 1.4301
Push-in ConnectionsStainless steel 1.4401 (working) / Stainless steel (supply)
Pneumatic DataOperating MediumCompressed air, neutral gases (ISO 8573-1:2010 Class 7.4.4)
Operating Pressure-1.0 bar to 10.0 bar (vacuum up to 10 bar)
Auxiliary Pilot Pressure3.0 bar to 10.0 bar (internal feed)
Nominal Flow Rate $Q_{\text{Nn}}$310 l/min (standard); reduced by ~3% with HotSwap
Width per Station11 mm
Total Valve Slots12 (expandable up to 24 slots / 48 functions in family)
Electrical DataOperating Voltage24 V DC (±10%), residual ripple 1 Vss
Coil Power Consumption0.7 W nominal (0.175 W after electronic power reduction)
Coil Current Draw29 mA nominal (10 mA after power reduction)
Duty CycleContinuous operation (100% ED)
Protection ClassClass III per DIN EN 61140 / VDE 0140
EnvironmentalDegree of ProtectionIP20 standalone; IP65 in closed cabinet with AirLINE Quick
Ambient Operating Temp.-10 °C to +55 °C
Storage Temperature-20 °C to +60 °C
Mounting OrientationUnrestricted (any orientation)

Type 8652 supports safety-related shut-off architectures through optional SIA (safety shut-off) variants and module-based safety shutdown modules. In these configurations, external dry contacts directly interrupt the 24 V DC coil power circuit without requiring fieldbus interaction.

Hazardous Area Special Conditions

When installed in Zone 2 / Zone 22 hazardous locations (ATEX II 3G Ex ec IIC Gc, II 3D Ex tc IIIC Dc, IECEx BVS 20.0024 U, cURus Class I Div 2), the valve island must be installed in an enclosure rated at least IP54 for gas atmospheres or IP6X for dust atmospheres. Do not disconnect electrical terminals or perform HotSwap valve replacements while energized unless the atmosphere is verified to be non-hazardous.

Spare Parts and Ordering Numbers ​

Article No.Component Description
20033486Type 8652 valve island, 12-bank, 10x CF-Z, 2x blind, 24 DI, D10/D6 VA, Industrial Ethernet
301377Type 6534 replacement valve, CF Z (5/2-way bistable impulse, 24 V DC, 290 l/min)
335779Dummy plate module for unpopulated valve slots
3848728DI electronic module with digital inputs (limit switch feedback)
384873Electronic module without digital inputs
301799ME43 fieldbus gateway module (PROFINET, EtherNet/IP, Modbus TCP, EtherCAT)
9201805-pin spring-loaded terminal block (electronics / communication power)
9204422-pin spring-loaded terminal block (AUX 24 V pneumatic coil power)
754961Height adapter for 12-fold AirLINE Quick base plate
60005567Retaining plate for 12-fold base plate (cabinet exterior mounting)
308661M5 × 10 A2 DIN 6912 fastening screw set (pack of 10)