Skip to content
ATEX / IECExDirect-actingMedia-separatedIP65

BURKERT 20070294 Type 0330 3/2-Way Direct-Acting Solenoid Valve Ex

Burkert 20070294 Type 0330 is a direct-acting 3/2-way explosion-proof solenoid valve. Features a stainless steel body, G1/4 internal thread, EPDM seal, 24V operation, and ATEX/IECEx certification.

BURKERT 20070294 Type 0330 3/2-Way Direct-Acting Solenoid Valve Ex

Burkert 20070294 Type 0330 is a direct-acting, media-separated pivoted armature solenoid valve. This specific explosion-proof variant features a 3/2-way distributing circuit function (CF F), a stainless steel body, and an EPDM seal. The solenoid coils are moulded with a chemically resistant epoxy, and the coil system is separated from the medium by a diaphragm, making it highly suitable for critical and aggressive media. It operates at 24 V and is certified for ATEX and IECEx hazardous locations.

General Technical Data

FeatureSpecification
Orifice1.00 mm
Body MaterialStainless steel (1.4401)
Seal MaterialEPDM (Ethylene-propylene-diene rubber)
Port ConnectionInternal thread G 1/4
Voltage24 V (AC/DC)
Pressure Range0...25 bar
Medium Temperature-30 °C to +90 °C
Ambient TemperatureMax. +55 °C
Degree of ProtectionIP65
Weight0.75 kg (Explosion-proof metal body)
Duty Cycle100% continuous operation
Thermal Insulation ClassEpoxy coil class H

Circuit Function

Circuit Function F (CF F) 3/2-way distribution valve (solenoid valve), direct-acting.

Burkert 20070294 Circuit function F 3/2-way distribution valve

Explosion Protection

Approvals

ATEX: II 2G Ex mb IIC T4 Gb, II 2D Ex mb IIIC T130 °C Db IECEx: Ex mb IIC T4 Gb, Ex mb IIIC T130 °C Db

Explosion Risk

The solenoid valve forms a closed system after installation. When used in explosion-risk areas, there is a risk of explosion if the system is opened in the operating state. Do not remove or open the system during operation.

Electrostatic Discharge

There is a risk of explosion in potentially explosive areas if there is a sudden discharge of electrostatically charged devices or individuals. Take appropriate measures to ensure that no electrostatic discharges can build up in the potentially explosive area.

Materials

ElementMaterial
CoilEpoxy
Diaphragm / O-ringEPDM
Seat / Valve bodyStainless steel (1.4401)

Dimensions

Explosion-proof Cable Variant

Burkert 20070294 Explosion-proof cable variant dimensions