BURKERT 20074343 (Type 8652 AirLINE) is a modular electro-pneumatic automation valve island engineered to control pneumatic actuators and process valves in industrial automation systems. Configured with a 24-bank base and a stainless steel AirLINE Quick (ALQ VA) adapter plate, this unit provides 48 discrete pneumatic control functions using 24 individual 2x 3/2-way CF-C (normally closed) valve slices. Each pneumatic pilot station incorporates Burkert Type 6164 pilot solenoid valves acting on Type 6534 pneumatic spool valves.

BURKERT 20074343 Type 8652 AirLINE modular valve island

Pneumatic Configuration and Process Connections ​

The 24-slot manifold incorporates stainless steel push-in fittings for harsh operating environments, featuring D10 supply connections and D6 working ports. Exhaust ports 3 (R) and 5 (S) integrate non-return check valves to prevent backpressure infiltration into inactive lines.

AttributeSpecification
Valve Island Type8652 AirLINE Standard Variant
Article Number20074343
Valve Slot Count24 slots (PCE)
Valve Positions 1 through 242x 3/2-way CF-C per position (48 functions total)
Supply Port ConnectionD10 push-in, Stainless steel
Working Port ConnectionsD6 push-in, Stainless steel
AirLINE Quick Interface MaterialStainless steel (VA)
Auxiliary Pilot AirExternal supply
Auxiliary Supply (Right)Push-in connector D6 and D10
Auxiliary Supply (Left)Push-in connector D6 and D10
Auxiliary Supply (Middle)Without intermediate auxiliary supply
Intermediate Feed Quantity1 PCE
Operating Pressure Range-1.00 bar to 10.00 bar (-0.1 MPa to 1.0 MPa)
Pilot Pressure Range3.00 bar to 10.00 bar (0.3 MPa to 1.0 MPa)
Fluid and Ambient Temperature-10.00 °C to +55.00 °C
Integrated Check ValvesPort 3 (R) and Port 5 (S)
Pneumatic HotSwap at Port 1 (P)No

Communication and Electrical Interface ​

BURKERT 20074343 features an integrated fieldbus gateway supporting multi-protocol Industrial EtherNet via RJ45 interfaces. The unit operates on a 24 V DC supply and does not include local digital input modules.

ParameterValue
Modular ArchitectureFieldbus module
Industrial EtherNet ProtocolsPROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic
Hardware InterfaceRJ45 Ethernet port
Operating Voltage24 V DC (±10%)
Nominal Current Consumption3 A (typical standard rating plate rating)
Digital Input Count0 (Electronic modules 1–6 without digital inputs)
Base Degree of ProtectionIP20 (IEC/EN 60529)

Hazardous Area Approvals and Identification Plates ​

BURKERT Type 8652 valve islands operating in potentially explosive atmospheres are certified under ATEX Directive 2014/34/EU, IECEx, and China Compulsory Certification (CCC via SITIIAS according to GB/T 3836.2021). The unit holds component type examination certificates BVS 20 ATEX E 031 U and IECEx BVS 20.0024 U issued by DEKRA Testing and Certification GmbH (Bochum), with PTB surveillance (CE0102).

Valve islands deployed in hazardous locations carry two nameplates: a general device nameplate and a dedicated explosion-protection label.

BURKERT 20074343 Type 8652 standard rating plate layout

PositionDescriptionData Example
1Device typeType 8652 AirLINE
2Pressure range3–10 bar
3Ambient temperature range-10 °C to +55 °C
4Rated voltage / Current consumption24 V DC / 3 A
5Serial numberS/N (factory assigned)
6Manufacturing codeEncoded production identifier
7Order / Article number20074343

BURKERT 20074343 Type 8652 hazardous location nameplate examples

PositionParameter DescriptionCode PX68 Rating PlateCode PU17 Rating Plate
1North American Zone (Gas)—Cl I, ZN 2, AEx ec IIC Gc / Ex ec IIC Gc U
2North American Zone (Dust)—Cl II, ZN 22, AEx tc IIIC Dc / Ex tc IIIC Dc U
3North American Division—Cl I, Div 2, Gr A, B, C, D / Cl II, III, Div 2, Gr F, G
4Explosion protection markEx markEx mark
5ATEX Certificate NumberBVS 20 ATEX E 031 UBVS 20 ATEX E 031 U
6ATEX Gas & Dust MarkingII 3G Ex ec IIC Gc / II 3D Ex tc IIIC DcII 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc
7IECEx Certificate NumberIECEx BVS 20.0024 UIECEx BVS 20.0024 U
8IECEx Gas & Dust MarkingEx ec IIC Gc / Ex tc IIIC DcEx ec IIC Gc / Ex tc IIIC Dc
9Safety WarningElectrical connection and hot-swap cautionsElectrical connection and hot-swap cautions

Enclosure and Thermal Ratings

Inside a control cabinet at a maximum ambient temperature of +55 °C, the assembly complies with temperature class T4 limits. When utilizing the AirLINE Quick interface mounted to the control cabinet base, the maximum exterior operating surface temperature does not exceed 80 °C.

Installation Rules and Operational Safety ​

Hazardous Area Installation Constraints

  • Enclosure Protection: Install Type 8652 in an enclosure certified for hazardous areas meeting EN/IEC 60079-0 and EN/IEC 60079-7 (minimum IP54 for category 3G/Gc) or EN/IEC 60079-31 (minimum IP6X for category 3D/tc).
  • Pollution Degree: The system must operate exclusively in micro-environments meeting pollution degree 2 or better according to IEC 60664-1.
  • Overvoltage Protection: Transient suppression must prevent peak supply voltage from exceeding 140% of the nominal 24 V DC supply interface rating.
  • De-energized Handling: In explosive atmospheres, terminal connections (24 V DC power, SIA, EVS, digital inputs) and fixed cables must only be connected or disconnected in a completely de-energized state. Hot-swap replacement of valves is prohibited in explosive atmospheres unless an approved testing procedure confirms the atmosphere is completely non-hazardous.

An auxiliary label stating WARNING DO NOT CONNECT OR DISCONNECT WHEN ENERGIZED is supplied with the valve island. Affix this label in a prominent position on the unit whenever cabinet installation limits visibility of the primary explosion protection nameplate.