Skip to content
Type 865220 Valve SlotsAirLINE Quick AluminiumIndustrial Ethernet2x 3/2-Way CF-CPneumatic HotSwapIP20 / IP65

BURKERT 20081486 Type 8652 20-Slot AirLINE Valve Island with AirLINE Quick Adapter

BURKERT 20081486 Type 8652 is a 20-slot AirLINE valve island with aluminium AirLINE Quick plate, 20x 2x3/2-way CF-C valves, Industrial Ethernet RJ45, integrated check valves, and pneumatic HotSwap.

BURKERT 20081486 Type 8652 20-Slot AirLINE Valve Island with AirLINE Quick Adapter

BURKERT 20081486 (Type 8652) is an electro-pneumatic automation valve island engineered for process automation environments. Configured as a 20-slot terminal with an anodised aluminium AirLINE Quick base adapter plate, this specific unit is factory-fitted with 20 double 3/2-way normally closed solenoid valves (circuit function C), delivering a total of 40 independently controllable pilot valve channels. The terminal includes an integrated pneumatic intermediate feed module to maintain uniform operating pressures across large valve banks, brass D 3/8" pneumatic supply connections, and brass D 1/4" working ports.

Communication is handled through an integrated Industrial Ethernet interface supporting PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, and CC-Link IE Field Basic over dual RJ45 connectors. The unit incorporates hardware-level safety and maintenance functions, including pneumatic HotSwap check valves in supply port 1 (P) that allow live valve replacement under line pressure, and integrated check valves in exhaust ducts 3 (R) and 5 (S) to eliminate unwanted actuator motion caused by exhaust pressure spikes.

Technical Configuration of Article 20081486 ​

Article 20081486 is manufactured according to the following specific configuration:

ParameterSource Specification
Article Number20081486
Valve Island TypeType 8652 AirLINE
Number of Valve Slots20 slots (20 PCE)
Valve Positions 1 to 202x 3/2-way CF-C (normally closed, servo-assisted)
Total Valve Functions40 functions
Supply Connection (1)Push-in connector D 3/8" (Brass)
Working Ports (2, 4)Push-in connectors D 1/4" (Brass)
Additional Supply (Left)Push-in connector 3/8" and 1/4"
Intermediate Feed Quantity1 unit included
AirLINE Quick Plate MaterialAnodised aluminium
Auxiliary Pilot AirInternal
Operating Pressure Range-1.00 bar to 10.00 bar (vacuum to 10 bar)
Pilot Pressure Range3.00 bar to 10.00 bar
Nominal Flow Rate QNn (Air)310 l/min (reduced by approx. 3% with HotSwap)
Communication ProtocolIndustrial Ethernet (PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, CC-Link IE Field Basic)
Hardware Interface2x RJ45 (ports X1 and X2)
Digital Inputs0 (without DI electronic module)
Degree of ProtectionIP20 (bare) / IP65 (inside sealed cabinet with AirLINE Quick)
Ambient & Medium Temperature-10 °C to +55 °C

General Technical Data ​

ParameterSpecification
Body MaterialPolyamide (PA)
Seal MaterialNBR and PUR
Station Width11 mm per valve slot
Nominal Operating ModeContinuous operation (100% duty cycle)
Switching Time MeasurementMeasured according to ISO 12238
Operating Voltage24 V DC (±10%)
Residual Ripple1 Vss
Power Consumption per Valve0.7 W (0.175 W after electronic power reduction)
Nominal Current per Valve29 mA (10 mA after power reduction)
Protection ClassClass III according to DIN EN 61140, VDE 0140
Operating MediumOil-free or lubricated compressed dry air, neutral gases (5 µm filter recommended)
Compressed Air QualityISO 8573-1:2010, Class 7.4.4
Storage Temperature-20 °C to +60 °C

AirLINE Quick Cabinet Integration ​

BURKERT 20081486 AirLINE Quick adapter plate design

The AirLINE Quick system allows direct assembly of the valve island into the cabinet floor or cabinet wall. By routing all working lines and air supply feeds directly through the cut-out of the cabinet bottom, bulkheads and intermediate bulkhead fittings are eliminated, reducing installation footprint and assembly time.

FeatureSpecification
Adapter Plate MaterialAnodised aluminium (also available in stainless steel 1.4301)
Working Port ConnectionsStainless steel 1.4401 or nickel-plated brass
Supply / Exhaust PortsPush-in D 10 mm (3/8")
Working PortsPush-in D 6 mm (1/4")
Mounting PositionCabinet wall or cabinet floor

Installation Clearance for HotSwap

When installing the valve island inside the control cabinet, maintain the minimum clearance from the cabinet front edge and rear mounting plate as specified in the Type 8652 manual to allow valve replacement while the system remains pressurized.

BURKERT 20081486 control cabinet installation and HotSwap clearance

Dimensions for 16-, 20-, and 24-Fold Terminals ​

BURKERT 20081486 Type 8652 16-, 20-, and 24-fold dimensions

Dimensions are stated in mm:

VariantABCDmm'n
16-fold with intermediate feed11222410 x M5114.3774
20-fold with intermediate feed (20081486)13426810 x M5158.31175
24-fold with intermediate feed15631210 x M5158.311116
16-fold without intermediate feed9919810 x M5—15—4
20-fold without intermediate feed12124210 x M5—19—5
24-fold without intermediate feed14328610 x M5—23—6

Pneumatic Safety & Switching Functions ​

Article 20081486 features 20 positions of Circuit Function C (2x 3/2-way solenoid valve, servo-controlled, normally closed, with manual override). Each station contains two independent 3/2-way valves within an 11 mm width, driving two process valve actuators per slice.

  • Integrated Exhaust Check Valves: Located in ducts 3 (R) and 5 (S), these non-return valves prevent pressure spikes in the common exhaust lines from triggering uncommanded valve movements in other connected actuators.
  • Pneumatic HotSwap Function: Integrated check valves in port 1 (P) allow any of the 20 valve slices to be unbolted and replaced under operational line pressure without shutting down adjacent processes. HotSwap implementation introduces an approximate 3% flow restriction compared to non-HotSwap variants.

Electrical & Fieldbus Connections ​

Electronics & Display Power Supply ​

Power to the internal electronics and LC display is supplied via a 5-pin spring-loaded terminal block (wire cross-section ≤ 1.5 mm²):

PinColour CodeFunction
1Red24 V DC
2WhiteCAN_H (büS connection)
3GreenShielding
4BlueCAN_L (büS connection)
5BlackGND (0 V DC)

Pneumatic Valve Power Supply ​

Coil power is separated from logic power and connected via a dedicated 2-pin spring-loaded terminal block on the interface plate:

TerminalColour CodeAssignment
1RedAUX 24 V DC
2BlackGND (0 V DC)

Industrial Ethernet Interface (RJ45) ​

BURKERT 20081486 Industrial Ethernet RJ45 port pinout

Communication ports X1 and X2 feature standard 8-pin RJ45 sockets configured for Industrial Ethernet:

PinSignalAssignment
1TX+Transmit Data +
2TX-Transmit Data -
3RX+Receive Data +
4N.C.Not connected
5N.C.Not connected
6RX-Receive Data -
7N.C.Not connected
8N.C.Not connected

Network Topology & Diagnostics ​

BURKERT 20081486 Industrial Ethernet network configuration topology

Type 8652 functions as an Industrial Ethernet master node on PROFINET IO, EtherNet/IP, Modbus TCP, EtherCAT, or CC-Link IE Field Basic networks, and can interconnect downstream büS valve islands as slaves.

  • LC Display: Shows operational status, channel indicators, clear text messages, and standardized diagnostic symbols directly at the island.
  • Controller Diagnostics: Diagnostic messages are passed cyclically and acyclically to the higher-level PLC.
  • Bürkert Communicator (Type 8920): Connects via USB büS interface (set 1, part 772426) for parameter configuration, process trend visualisation, firmware updates, and full backup/restore routines.

Explosion Protection & Operating Restrictions ​

Type 8652 valve islands hold certifications for hazardous locations under ATEX, IECEx, CCC, and UL HazLoc:

  • ATEX: BVS 20 ATEX E 031 U, II 3G Ex ec IIC Gc / II 3D Ex tc IIIC Dc
  • IECEx: IECEx BVS 20.0024 U, Ex ec IIC Gc / Ex tc IIIC Dc
  • North America (cURus): Class I, Zone 2, AEx ec IIC Gc / Class II, Zone 22, AEx tc IIIC Dc; Class I, Division 2, Groups A, B, C, D / Class II, III, Division 2, Groups F, G
  • CCC: Certified for hazardous applications in China

Hazardous Area Usage Conditions

When installed in explosive gas or dust atmospheres:

  • The valve island must be housed in an enclosure meeting EN/IEC 60079-0 with a minimum degree of protection of IP54 for gas (3G/Gc) and IP6X for dust (3D/Dc).
  • The pollution degree must not exceed degree 2 according to IEC 60664-1.
  • Do not connect or disconnect electrical terminals (24 V supply, SIA, EVS, DI) when an explosive atmosphere is present.
  • The HotSwap function must never be used in a potentially explosive atmosphere unless the atmosphere has been proven non-explosive by gas testing instruments.
  • Clean surfaces exclusively with a damp or antistatic cloth to prevent electrostatic discharge.

Compatible Accessories & Replacement Parts ​

Item DescriptionQuantityArticle No.
Replacement Valve Type 6534 (2x 3/2-way CF-C, 24 V DC)1301374 (Spare set REF 296031)
Dummy Valve Plate1335779 (REF 327614)
Height Adapter for 20-fold with intermediate feed1754963
Retaining Plate for 20-fold with intermediate feed (cabinet exterior)160005569
Blind Plate for 20-fold with intermediate feed1754968
Fastening Screw Set M5 x 10 A2 DIN 691210308661
5-Pin Spring-Loaded Terminal (Electronics & Display)1920180
2-Pin Spring-Loaded Terminal (Valve Power Supply)1920442
USB büS Interface Set 1 (Type 8923) for Bürkert Communicator1772426