BURKERT 462468 (Type 0131) is a 2/2-way direct-acting media-separated solenoid valve with PVC body, EPDM seals, NPT 1/2 ports, DN 15 orifice, 0-1 bar operating pressure, and 24 V AC/DC Kick and Drop coil.

BURKERT 462468 (Type 0131) is a direct-acting, media-separated 2/2-way toggle solenoid valve configured with circuit function A (normally closed). Built with a rigid polyvinyl chloride (PVC) valve body, ethylene-propylene-diene rubber (EPDM) seals, and female NPT 1/2 process connections, the valve is engineered for controlling and shutting off aggressive or non-aggressive media without metallic fluid contact. The 15 mm nominal orifice provides a water flow rate (Kv) of 4.5 m³/h and an air flow rate (QNn) of 4,800 l/min across an operating pressure range from 0 bar up to 1 bar, with full technical vacuum capability.
The electromagnetic actuator features an epoxy-encapsulated Class H coil system with integrated "Kick and Drop" electronics operating on 24 V AC/DC. The internal circuit delivers a 100 W high-power inrush pulse to actuate the stainless steel plunger, dropping holding power to 9 W after pull-in to minimize electrical power consumption and internal coil heating. Media separation is achieved via an internal diaphragm barrier that isolates the actuator assembly from corrosive line chemicals. The assembly includes an integrated manual override with a 90° turn-lock mechanism for manual operation during commissioning and servicing.
| Parameter | Specification |
|---|---|
| Type | 0131 |
| Article Number | 462468 |
| Circuit Function | CF A (2/2-way valve, normally closed) |
| Valve Construction | Complete direct-acting toggle valve |
| Media Separation | Yes (diaphragm isolation) |
| Nominal Diameter (DN) | 15 mm (9/16") |
| Port Connection | Female thread NPT 1/2 |
| Operating Pressure Range | 0.00 bar - 1.00 bar (vacuum capable) |
| Flow Factor Kv (Water) | 4.5 m³/h |
| Flow Rate QNn (Gas) | 4,800 l/min |
| Operating Voltage | 24 V AC/DC (50/60 Hz, tolerance ±10%) |
| Inrush Power Consumption | 100 W (UC) |
| Holding Power Consumption | 9 W (UC) |
| Duty Cycle | 100% continuous operation |
| Switching Frequency | Max. 6/min (with UC electronics) |
| Opening Time | 10 - 20 ms |
| Closing Time | 40 - 60 ms |
| Medium Temperature Range | -10 °C to +50 °C |
| Ambient Temperature Range | -10 °C to +50 °C |
| Maximum Fluid Viscosity | 37 mm²/s |
| Permissible Flow Velocity | 2.5 m/s (DN 15) |
| Degree of Protection | IP65 (with DIN EN 175301-803 Form A cable plug) |
| Manual Override | Mechanical lever with 90° twist lock |
BURKERT 462468 operates in Circuit Function A (CF A). When unpowered, the internal valve seat remains closed by spring and toggle force. Energizing the 24 V solenoid lifts the plunger, moving the toggle mechanism and opening the direct fluid path from inlet port 1 (P/NC) to the outlet port.

The toggle pin transmits mechanical force from the dry core tube to the closing body across a flexible seal diaphragm. Because no process fluid enters the magnetic core chamber, aggressive process chemicals cannot corrode the metallic plunger or guide tube. With PVC body construction and EPDM elastomers, the valve handles alkalis, alkaline washing and bleaching solutions, water, and non-aggressive technical vacuum circuits up to 50 °C.

| Item | Component | Material |
|---|---|---|
| 1 | Coil | Epoxy (insulation class H) |
| 2 | Plunger | Stainless steel 1.4105 |
| 3 | Toggle pin | PTFE |
| 4 | True union nut | Polyvinyl chloride (PVC) |
| 5 | O-ring | Ethylene-propylene-diene rubber (EPDM) |
| 6 | Connection fitting | PVC (threaded NPT 1/2) |
| 7 | Body | Polyvinyl chloride (PVC) |
| 8 | Closing body | Ethylene-propylene-diene rubber (EPDM) |
| 9 | O-ring | Ethylene-propylene-diene rubber (EPDM) |
| 10 | Lateral flange | Polycarbonate (PC) |
| 11 | Manual override | Mechanical assembly with locking tab |

BURKERT 462468 features internal NPT 1/2 pipe connections integrated into a true union plastic body. Dimensions conform to the 2/2-way plastic valve table with true union nut and connection fitting:
| Material | DN | Connection | Dimension B (mm) | Dimension C (mm) | Thread D | Overall Length L1 (mm) | Center Height L2 (mm) |
|---|---|---|---|---|---|---|---|
| PVC | 15 | Threaded | 19 | 14 | NPT 1/2 | 136 | 103.0 |
Electrical interconnection is established through male plug contacts according to DIN EN 175301-803 Form A, designed to mate with cable plugs such as BURKERT Type 2518. When properly mated and fastened with the central retaining screw (maximum torque 1 Nm), the assembly provides IP65 environmental ingress protection.
Energy-Saving Kick and Drop Technology
The integrated UC electronics deliver full inrush power (100 W) for fast, positive armature attraction during the first switching phase. Power then drops automatically to 9 W hold mode. The circuit includes a resettable internal temperature protection switch that safely shuts down the coil if impermissible heating occurs during excessive switching frequency.
Continuous Operation Recommendation
During prolonged continuous operation or long periods of inactivity, operate the valve at least 1 to 2 times per day to ensure functional safety and prevent seal adhesion.
Prior to piping installation, flush lines thoroughly to remove foreign debris. Always mount an upstream particulate strainer (filter rating ≤ 500 µm) ahead of the valve inlet.
Installation Guidelines

BURKERT 462468 includes a manual override mechanism on the valve body. To actuate manually, depress the override pin and rotate it 90° clockwise until it hits the mechanical stop.
Manual Override Interlock
When the manual override is locked in the operated position, the valve cannot be closed or actuated electrically. Return the override to its neutral position before resuming electrical system control.
Periodic maintenance involves verifying seal integrity, confirming tight mechanical connections, and verifying that the maximum fluid flow velocity of 2.5 m/s is not exceeded.
| Fault Observed | Possible Cause | Corrective Action |
|---|---|---|
| Valve does not actuate | Short circuit or interrupted coil | Check electrical supply and coil resistance |
| Valve does not actuate | Operating pressure exceeds 1 bar | Verify line pressure is within 0 to 1 bar limit |
| Valve does not actuate | Manual override locked | Disengage manual override mechanism |
| Valve does not close | Foreign particulate inside valve seat | Disassemble and clean valve interior |
| Valve does not close | Manual override locked in open position | Rotate manual override counter-clockwise to unlock |

Original replacement parts are grouped into structured factory kits:
When ordering replacement kits, specify the target kit item along with the device article number 462468.