BURKERT 462569 (Type 0330) is a direct-acting 3/2-way pivoted armature solenoid valve, brass body, FKM seal, NPT 1/4, 4 mm orifice, -1 to 3 bar vacuum rating, 120V 60Hz coil, and IP65 protection.

BURKERT 462569 (Type 0330) is a direct-acting 3/2-way pivoted armature solenoid valve configured in circuit function C (normally closed) with an integrated media-separating diaphragm. Designed for demanding gaseous and liquid media, article 462569 features a brass body, FKM seals, an orifice size of 4.0 mm (Kv 0.23 m³/h, QNn 255 l/min), and NPT 1/4 female threaded ports. The solenoid actuator is isolated from the fluid chamber by the diaphragm system, preventing media contact with the magnetic core assembly and eliminating corrosion risks. This unit operates across a pressure range of -1.00 bar to 3.00 bar, providing vacuum service, and is powered by a 120 V AC, 60 Hz epoxy coil rated for 100% ED continuous operation.
Article 462569 delivers fast cycle times and media isolation in neutral and aggressive fluids with a viscosity of up to 37 mm²/s.
| Specification Parameter | Value |
|---|---|
| Article Number | 462569 |
| Valve Type | 0330 |
| Circuit Function | C (3/2-way, normally closed: P/NC closed, A/OUT to R/NO connected) |
| Orifice Size | DN 4.0 mm (5/32") |
| Flow Coefficients | Kv (water): 0.23 m³/h; QNn (gas): 255 l/min |
| Pressure Range | -1.00 bar to 3.00 bar (Vacuum variant NA02) |
| Port Connection | NPT 1/4 female thread |
| Valve Body Material | Brass (MS) |
| Valve Seat Material | Brass (MS) |
| Sealing Material | FKM (Fluor rubber, Shore hardness 70) |
| Operating Voltage | 120 V AC (60 Hz), tolerance ±10% |
| Coil Power Consumption | Inrush: 30 VA, Hold: 15 VA / 8 W |
| Coil Insulation Class | Class H (Epoxy encapsulation) |
| Duty Cycle | 100% continuous operation (100% ED) |
| Switching Times | Opening: 8 to 15 ms, Closing: 8 to 15 ms (at 20 °C, 6 bar) |
| Medium Temperature Range | 0 °C to +90 °C |
| Permissible Ambient Temperature | Max. +55 °C (Storage: -40 °C to +80 °C) |
| Electrical Protection Degree | IP65 according to DIN EN 60529 / IEC 60529 (with cable plug) |
Type 0330 isolates the coil mechanism from process media using a flexible separating diaphragm. The fluid chamber and body materials resist chemical breakdown when handling oxidizing acids, hot oils with additives, salt solutions, and waste gases compatible with brass and FKM.

| Item Number | Component | Material |
|---|---|---|
| 1 | Solenoid Coil | Epoxy encapsulation |
| 2 | Diaphragm | FKM (Fluor rubber) |
| 3 | O-Ring | FKM (Fluor rubber) |
| 4 | Valve Seat | Brass |
| 5 | Valve Body | Brass |
Media Compatibility Verification
Verify specific chemical combinations using the Bürkert resistApp tool prior to handling unlisted corrosive compounds. For media with particulates, install upstream filtration to protect the sealing surface.
Circuit function C operates as a 3/2-way normally closed valve. In the de-energized rest state, pressure port 1 (P) is shut off, while working port 2 (A) vents to exhaust port 3 (R). When energized, the pivoted armature shifts, connecting port 1 (P) directly to port 2 (A), while shutting off exhaust port 3 (R).

| Circuit Function | Connection Port 1 | Connection Port 2 | Connection Port 3 |
|---|---|---|---|
| A (2/2-way NC) | P | A | — |
| B (2/2-way NO) | B | P | — |
| C (3/2-way NC, 462569 standard) | P | A | R |
| D (3/2-way NO) | R | B | P |
| E (3/2-way Mixing) | P1 | A | P2 |
| F (3/2-way Distribution) | A | P | B |
| T (3/2-way Universal) | NC | IN / OUT | NO |
The internal compression springs in Type 0330 valves are factory-matched to the specified circuit function. If a function C valve is connected in alternative circuit arrangements, the permissible operating pressure changes according to the following ratings for a DN 4 metal body valve:
| Original Valve Function | Target Circuit Function A | Target Circuit Function B | Target Circuit Function C | Target Circuit Function D | Target Circuit Function E | Target Circuit Function F |
|---|---|---|---|---|---|---|
| Function C (DN 4 Metal) | 5.0 bar | 0.8 bar | 5.0 bar | 0.8 bar | 0.8 bar | 5.0 bar |
Article 462569 features an overall installation body length of 46 mm and female NPT 1/4 threaded ports on a brass valve housing. Bottom mounting holes follow a standardized 38 mm x 24 mm pattern for secure mechanical support.

| Thread Designation D1 | Thread Length L1 | Thread Designation D2 | Thread Length L2 |
|---|---|---|---|
| G 1/8 | 9.0 mm | — | — |
| G 1/4 | 9.0 mm | NPT 1/4 | 7.5 mm |
Upstream Filtration Requirement
For safe operation of the solenoid valve, a dirt trap with mesh size ≤ 500 µm must be installed upstream of the valve inlet. Check pipelines for debris and flush before connecting.
Type 0330 incorporates a lockable manual override on the actuator housing to assist commissioning, testing, and manual override cycles.

Manual Override Interlock
When the manual override is rotated clockwise into the locked position, the valve cannot be electrically actuated. Always return the override to its neutral position before resuming electrical control.
Electrical connection is established via plug contacts matching Form A according to DIN EN 175301-803 (DIN 43650 Design A), suitable for cable plug Type 2518 or Type 2509.

| Position | Description | Position | Description |
|---|---|---|---|
| 1 | Valve Type (0330) | 7 | Nominal Pressure (PN) |
| 2 | Circuit Function (C) | 8 | Active Coil Power (8 W) |
| 3 | Orifice (4.0 mm) | 9 | Manufacturing Code |
| 4 | Sealing Material (FKM) | 10 | Article Number (462569) |
| 5 | Body Material (Brass MS) | 11 | Supply Voltage (120 V / 60 Hz) |
| 6 | Connection Type (NPT 1/4) |
De-energize and Depressurize
Before performing maintenance or disassembling the valve from the piping system, turn off the line pressure, drain and deaerate all lines, and switch off electrical power to prevent accidental energization.
| Fault Condition | Probable Cause | Corrective Action |
|---|---|---|
| Valve does not actuate | Solenoid coil interrupted or short circuit | Check electrical wiring, supply voltage, and coil resistance. |
| Operating pressure out of specification | Verify supply pressure is within -1.0 to 3.0 bar range. | |
| Manual override locked in actuated position | Unlock manual override by turning counter-clockwise. | |
| Valve does not close | Valve interior contaminated with particulates | Disassemble valve body and clean internal seats and diaphragm. |
| Manual override locked | Return manual override to unlocked neutral position. | |
| Media leakage at body joint | Fastening screws loose or seal deteriorated | Inspect FKM diaphragm and O-ring; retighten body screws evenly. |