PN25
Yoshitake GP-1210 remote air-loading pressure reducing valve for steam. Ductile cast iron body, JIS Rc screwed connection, 0.1-1.0 MPa inlet pressure.

Yoshitake GP-1210 is a remote air-loading type pressure reducing valve designed for steam applications. It features a ductile cast iron body with JIS Rc screwed connections and operates with an inlet pressure range of 0.1 to 1.0 MPa. The air-loaded design allows for precise reduced pressure control from 0.05 to 0.9 MPa by adjusting the loading air pressure.
| Specification | Value |
|---|---|
| Application | Steam |
| Inlet pressure | 0.1-1.0 MPa |
| Reduced pressure | 0.05-0.9 MPa 90% or less of inlet pressure (gauge pressure) |
| Minimum differential pressure | 0.05 MPa |
| Maximum pressure reduction ratio | 20:1 |
| Maximum temperature | 220°C |
| Valve seat leakage | 0.01% or less of rated flow |
| Body | Ductile cast iron |
| Valve, valve seat | Stainless steel |
| Piston, Cylinder | Brass or bronze |
| Connection | JIS Rc screwed |
Note
Available with trim parts (piston and cylinder) made of stainless steel (GP-1210S).

| Nominal size | d | L (mm) | H1 (mm) | H (mm) | Weight (kg) |
|---|---|---|---|---|---|
| 15A | Rc 1/2 | 150 | 64 | 220 | 7.0 |
| 20A | Rc 3/4 | 155 | 64 | 220 | 7.0 |
| 25A | Rc 1 | 160 | 67 | 235 | 8.5 |
| 32A | Rc 1-1/4 | 190 | 82 | 258 | 12.0 |
| 40A | Rc 1-1/2 | 190 | 82 | 258 | 12.5 |
| 50A | Rc 2 | 220 | 93 | 282 | 18.0 |